{"id":3291,"date":"2021-12-25T01:25:12","date_gmt":"2021-12-25T09:25:12","guid":{"rendered":"https:\/\/wonghoi.humgar.com\/blog\/?p=3291"},"modified":"2021-12-25T01:25:13","modified_gmt":"2021-12-25T09:25:13","slug":"rs-232-stop-bits-in-agilent-instruments","status":"publish","type":"post","link":"https:\/\/wonghoi.humgar.com\/blog\/2021\/12\/25\/rs-232-stop-bits-in-agilent-instruments\/","title":{"rendered":"RS-232 Stop Bits in Agilent Instruments"},"content":{"rendered":"\n<p>Turns out Agilent instruments do not use the same defaults for the RS-232 in their instruments. <\/p>\n\n\n\n<p>54600 series uses 1 <strong>stop <\/strong>bits (most common):<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"486\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-8-1024x486.png\" alt=\"\" class=\"wp-image-3293\" srcset=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-8-1024x486.png 1024w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-8-300x142.png 300w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-8-768x364.png 768w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-8.png 1176w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>RS-232 modules used in old 54600 series<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"112\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-7-1024x112.png\" alt=\"\" class=\"wp-image-3292\" srcset=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-7-1024x112.png 1024w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-7-300x33.png 300w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-7-768x84.png 768w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-7.png 1187w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>54620\/54640 series (newer 54600 series)<\/figcaption><\/figure>\n\n\n\n<p>However other bench instruments such as power supplies (E3640 series 663X series) and 33120A arbitrary waveform generator uses 2 stop bits (<strong>fixed<\/strong> regardless of parity), which is usually NOT THE DEFAULT for most terminal clients:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"882\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-10-1024x882.png\" alt=\"\" class=\"wp-image-3295\" srcset=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-10-1024x882.png 1024w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-10-300x258.png 300w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-10-768x661.png 768w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-10.png 1028w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>E3640 series and 33120A&#8217;s RS-232 configuration. <br>Parity only trade away one data bit, so it does not affect stop bit<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"231\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-9-1024x231.png\" alt=\"\" class=\"wp-image-3294\" srcset=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-9-1024x231.png 1024w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-9-300x68.png 300w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-9-768x173.png 768w, https:\/\/wonghoi.humgar.com\/blog\/wp-content\/uploads\/2021\/12\/image-9.png 1240w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>663X series powers supplies&#8217; programming manual aren&#8217;t explicit about that except in code example<\/figcaption><\/figure>\n<div class=\"pvc_clear\"><\/div><p id=\"pvc_stats_3291\" class=\"pvc_stats all  \" data-element-id=\"3291\" style=\"\"><i class=\"pvc-stats-icon medium\" aria-hidden=\"true\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"far\" data-icon=\"chart-bar\" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\" class=\"svg-inline--fa fa-chart-bar fa-w-16 fa-2x\"><path fill=\"currentColor\" d=\"M396.8 352h22.4c6.4 0 12.8-6.4 12.8-12.8V108.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v230.4c0 6.4 6.4 12.8 12.8 12.8zm-192 0h22.4c6.4 0 12.8-6.4 12.8-12.8V140.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v198.4c0 6.4 6.4 12.8 12.8 12.8zm96 0h22.4c6.4 0 12.8-6.4 12.8-12.8V204.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v134.4c0 6.4 6.4 12.8 12.8 12.8zM496 400H48V80c0-8.84-7.16-16-16-16H16C7.16 64 0 71.16 0 80v336c0 17.67 14.33 32 32 32h464c8.84 0 16-7.16 16-16v-16c0-8.84-7.16-16-16-16zm-387.2-48h22.4c6.4 0 12.8-6.4 12.8-12.8v-70.4c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v70.4c0 6.4 6.4 12.8 12.8 12.8z\" class=\"\"><\/path><\/svg><\/i> <img loading=\"lazy\" decoding=\"async\" width=\"16\" height=\"16\" alt=\"Loading\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/plugins\/page-views-count\/ajax-loader-2x.gif\" border=0 \/><\/p><div class=\"pvc_clear\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Turns out Agilent instruments do not use the same defaults for the RS-232 in their instruments. 54600 series uses 1 stop bits (most common): However other bench instruments such as power supplies (E3640 series 663X series) and 33120A arbitrary waveform &hellip; <a href=\"https:\/\/wonghoi.humgar.com\/blog\/2021\/12\/25\/rs-232-stop-bits-in-agilent-instruments\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n<div class=\"pvc_clear\"><\/div>\n<p id=\"pvc_stats_3291\" class=\"pvc_stats all  \" data-element-id=\"3291\" style=\"\"><i class=\"pvc-stats-icon medium\" aria-hidden=\"true\"><svg aria-hidden=\"true\" focusable=\"false\" data-prefix=\"far\" data-icon=\"chart-bar\" role=\"img\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\" class=\"svg-inline--fa fa-chart-bar fa-w-16 fa-2x\"><path fill=\"currentColor\" d=\"M396.8 352h22.4c6.4 0 12.8-6.4 12.8-12.8V108.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v230.4c0 6.4 6.4 12.8 12.8 12.8zm-192 0h22.4c6.4 0 12.8-6.4 12.8-12.8V140.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v198.4c0 6.4 6.4 12.8 12.8 12.8zm96 0h22.4c6.4 0 12.8-6.4 12.8-12.8V204.8c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v134.4c0 6.4 6.4 12.8 12.8 12.8zM496 400H48V80c0-8.84-7.16-16-16-16H16C7.16 64 0 71.16 0 80v336c0 17.67 14.33 32 32 32h464c8.84 0 16-7.16 16-16v-16c0-8.84-7.16-16-16-16zm-387.2-48h22.4c6.4 0 12.8-6.4 12.8-12.8v-70.4c0-6.4-6.4-12.8-12.8-12.8h-22.4c-6.4 0-12.8 6.4-12.8 12.8v70.4c0 6.4 6.4 12.8 12.8 12.8z\" class=\"\"><\/path><\/svg><\/i> <img loading=\"lazy\" decoding=\"async\" width=\"16\" height=\"16\" alt=\"Loading\" src=\"https:\/\/wonghoi.humgar.com\/blog\/wp-content\/plugins\/page-views-count\/ajax-loader-2x.gif\" border=0 \/><\/p>\n<div class=\"pvc_clear\"><\/div>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[44,36,11],"tags":[],"class_list":["post-3291","post","type-post","status-publish","format-standard","hentry","category-hardware","category-industrial-automation","category-measurement-equipment"],"_links":{"self":[{"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/posts\/3291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/comments?post=3291"}],"version-history":[{"count":1,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/posts\/3291\/revisions"}],"predecessor-version":[{"id":3296,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/posts\/3291\/revisions\/3296"}],"wp:attachment":[{"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/media?parent=3291"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/categories?post=3291"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wonghoi.humgar.com\/blog\/wp-json\/wp\/v2\/tags?post=3291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}